康晨希供應(yīng)MESALABS CI-BDTLF-121 BD測(cè)試包
產(chǎn)品Bowie-Dick Tset Pack 簡(jiǎn)稱BD測(cè)試包,用于滅菌器的預(yù)真空實(shí)驗(yàn)。 康晨希供應(yīng)MESALABS BD測(cè)試包產(chǎn)品為一個(gè)多層紗布的包裹,包裹內(nèi)部是一個(gè)測(cè)試卡片,模擬空氣排除實(shí)驗(yàn),根據(jù)其中測(cè)試卡片的顏色變化,判斷實(shí)驗(yàn)是否成功。

 

 

品牌其他品牌應(yīng)用領(lǐng)域醫(yī)療衛(wèi)生,環(huán)保,化工,生物產(chǎn)業(yè),石油

康晨希供應(yīng)MESALABS CI-BDTLF-121 BD測(cè)試包


? Air Removal Test Pack – Intended to evaluate the performance of the Air Removal (vacuum) system of Pre-Vacuum equipped Steam Sterilizers.

空氣排出測(cè)試包-評(píng)估預(yù)真空蒸汽滅菌器的空氣排除(真空)性能。

? Pre-assembled, disposable test pack. After exposure, unwrap pack and remove the indicator sheet for your records.

預(yù)裝配的一次性測(cè)試包。滅菌后,解開包裹,取出試紙記錄結(jié)果。

? 510(k) notification and meets AAMI, EN-867-3 and ISO 11140 air removal test.

符合510(k),AAMI,EN-867-3和ISO11140空氣排除測(cè)試標(biāo)準(zhǔn)。

? Lead Free Ink on Indicator Sheet – Safer for medical personnel and the environment.

試紙采用無(wú)鉛油墨-保證醫(yī)療人員和環(huán)境的安全。

? Distinct, non-reversible pink to black color change – easy to interpret.

*的不可逆的粉紅色到黑色的變化-容易判讀。

 




滅菌前                                 滅菌成功                                滅菌失敗

Procedures for Use

  • Test sterilizer once a day.

  • Test at the beginning of each day. A shortened cycle should be used to preheat the system (i.e. omit the drying phase). If the sterilizer is in continual use, then testing can be performed at any time, but it should be tested at the same time every day.

  • Place the pack on the bottom rack in the front section of the sterilizer, near the door and over the drain.

  • The test is most accurate when nothing else is in the chamber, so do not use this cycle to sterilize items or packs. Other items in this cycle may invalidate the test.

  • Run a pre-vacuum cycle following the parameters printed on the indicator instructions. You may eliminate the drying phase to save time without affecting the test.

  • After the cycle is complete, remove the pack and open to examine the indicator sheet. CAUTION! Test pack may still be hot so use caution when handling to avoid injury.

  • Record the necessary information on the sheet (or in a log book) and store for your records.

  • The filter paper pack can be discarded into a paper recycle bin.

產(chǎn)品實(shí)物圖:康晨希供應(yīng)MESALABS BD測(cè)試包


   


 

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

上??党肯?shí)業(yè)發(fā)展有限公司

版權(quán)所有    網(wǎng)站地圖    滬ICP備2020038427號(hào)-1    技術(shù)支持:化工儀器網(wǎng)


地址:上海市奉賢區(qū)南橋運(yùn)河北路1025號(hào)1幢0779室
在線客服